Insertion of a subclavian line with a landmark technique is a potentially life saving option in a particular cohort of critically unwell trauma patients – specifically those patient who are either periarrest or in actual cardiac arrest due to severe haemorrhagic shock where no other large bore IV access has been achieved.
THIS PROCEDURE SHOULD ONLY BE UNDERTAKEN BY ADVANCED TRAUMA CLINICIANS TRAINED IN THE PLACEMENT OF THESE LINES
From: Thoracic upper limb veins by OpenStax College, licenced under CC-BY-3.0
The subclavian vein is a continuation of the axillary vein which passes over the 1st rib, lying anterior to scalene tubercle. It runs parallel to the subclavian artery but is separated from it by scalenus anterior muscle. It is covered in its entire course by the clavicle, costo-clavicular ligament and subclavius muscle. Held in position (and thus patency remained) by fascia colli media. It remains patulous and undisplaced even in the hypovolaemic patient.
Generally the right side is the preferred site of subclavian access. Significant degloving injury, suspected vascular injury to ipsilateral subclavian vessels or ipsilateral clavicle fracture can all prompt use of the opposite side. A pre-existent pneumothorax makes insertion of the line on the ipsilateral side the preferred site.
By comparison, the internal jugular vein (IJV) is less suitable during trauma resuscitation due to its collapsibility in hypovolaemia and the need to remove cervical splinting and rotate a potentially injured cervical spine.
The femoral route is a viable alternative but its main drawbacks include:
Intraosseous access (preferably in the humeral site in a shocked trauma patient) is an option of course, but the flow rates achievable are much less than with a large bore central line even with a pressure bag – approx 100 ml/minute compared to up to 500 ml/min. They are also prone to displacement with arm movement which often occurs in a trauma resuscitation to facilitate procedures such as thoracostomy.
Subclavian trauma lines are intended for adult patients (over 16 yo) who are the victim of hypovolaemia secondary to trauma or in traumatic cardiac arrest plus with inadequate IV access and requiring time critical intervention.
In most cases it is anticipated that other forms of access have failed or are insufficient for patient need. A 12Fr triple lumen line can achieve flow rates of 500ml/min.
AS MENTIONED PREVIOUSLY – ONLY TRAINED CLINICIANS SHOULD ATTEMPT THIS PROCEDURE
Risks:
Personal protective equipment:
Cleaning equipment:
NOTE: AS THIS IS AN EMERGENCY PROCEDURE AND THE PATIENT IS LIKELY HAVING OTHER INTERVENTIONS UNDERTAKEN, FULL CLAB DRAPING OF THE ENTIRE BODY MIGHT NOT BE POSSIBLE
The CVL kit:
Securing:
While ultrasound is utilised for subclavian line insertion in medically well patients, in the crashing trauma patient use of USS is likely to cause a significant time delay unless used by practitioners that are highly skilled in ultrasound guided subclavian line insertion. We are therefore advocating a landmark approach for the majority of users.
The landmark for needle insertion is 1cm inferior to the junction of the middle and medial 1/3 of the clavicle
This corresponds to being 1cm inferior to the deltopectoral groove and one fingerbreadth lateral to the angle of the clavicle if these landmarks are palpable.
Point of puncture is 1-2cm inferior to junction of the middle and medial thirds of the clavicle. Aim directly across to the point at the top of the sternal notch (put your index finger there). The angle of needle insertion should be shallow and flat to prevent puncturing the lung
The steps for performing the infra-clavicular approach are as follows:
Wire kinking
Continuously pull back the wire to maintain tension on the wire as the dilator is advances. This will prevent the wire from kinking. The guidewire and dilator should never be advanced as a single unit. The wire should serve as an fixed monorail over which the dilator (or catheter) slides.
Difficulty advancing the dilator
If you have difficulty advancing the dilator due to poor skin turgor (aka floppy skin), have an assistant hold tension on the skin to prevent sliding of the subcutaneous tissue.
Difficulty advancing the dilator may be due to a small uncut skin-tag between the wire and your skin nick.
Another possibility for difficulty in advancing the dilator may be due to the wire being kinked or the wire having been pushed out of proper alignment. With the tip of the dilator in the subcutaneous tissue, gently pull the wire out of the patient 1-2cm.
The following video demonstrates the insertion of a subclavian line using a landmark technique. It also includes an introduction to CVLs and the seldinger technique. For those familiar with this, skip to 5:41 for a demonstration of the landmarks and 9:03 for the insertion technique.
SUBCLAVIAN CENTRAL VENOUS CATHETERIZATION Theory & Practice
First published: September 2026 (Author: Emma Batistich)
Approved by: Northern Region Trauma Network, Health New Zealand | Te Whatu Ora – Northern Region, NRHL, St John
Review due: 2 years